Talk:Mod:Hunt Research Group/IL cpmd functional
Which functional to choose for [bmim]Cl using CPMD
Notes by Ling
1. My [bmim][BF4] uses BLYP
2. Barbara Kirchner's group:
Zah10: [CH3NH3][NO3] uses BP86 for [CH3NH3][NO3] and BLYP for water. Code: CPMD.
Tha09: 32 pairs [emim][SCN] uses PBE for [emim][SCN] and BLYP for water. Code: CP2K.
3. Del Popolo's group:
Pop07: 8 pairs [mmim][PF6]; 4 pairs [emim][PF6]; 2 pairs [bmim][PF6]; 8 pairs [ddmim][PF6] uses LDA or PBE. Code: SIESTA.
Pop05: 8 and 24 pairs [dmim]Cl uses PBE. Code: SIESTA.
Pop06: 8 pairs [dmim]Cl uses PBE. Code: SIESTA.
Pra06: 8 pairs [dmim]Cl uses PBE. Code: SIESTA.
4. Balasubramanian's group:
Bha07: 12 pairs [bmim][PF6] + 28 pairs CO2 uses BLYP. Code: CPMD.
fictitious electron mass of 700 a.u. (increasing the fictitious electron mass might lead to the need of more MD steps to have the electronic system equilibrated.
time step of 5 a.u. (around 0.12 fs)
cutoff 90 Ry
5. Others:
Gha07: 10 pairs [bmim]I. Code: CPMD. They haven't specified which functional!
Bag07: 9 and 20 pairs [emim]Cl uses PBE. Code: CPMD.
Buh05: 25 and 41 pairs [dmim]Cl uses BP86. Code: CPMD.
6. Conclusion:
Most GGAs have similar behaviours for most properties. So I would not expect big differences between BLYP, PBE, PW91, BP86, etc.
My simulation is most similar to Balasubramanian's Bha07. => Choose BLYP.